    Home Automation Wiring Scheme

    Table of Contents
    Submission by Keith Doxey The cable marking system employed uses bands of coloured insulating tape to identify the different cables. It is much quicker than some of the adhesive tapes printed with numbers, and more rugged than writing on the sheath of the cable.

    From past experience I have found that even when using a permanent marker the ink still gets rubbed off or becomes illegible due to handling or dirt getting on the cable sheath. An added advantage of using coloured tape is that the cables can be identified from across the room.

    The scheme chosen for this installation uses 4 bands of tape using 4 colours. This gives 4x4x4x4 = 256 possible combinations to mark the cables. To increase the capacity of the system either add an extra colour or another band of tape.

    4 bands of 4 colours gives 256 combinations
    4 bands of 5 colours gives 625 combinations
    5 bands of 4 colours gives 1024 combinations
    5 bands of 5 colours gives 3125 combinations

    If your wiring scheme needs more than that, I would love to see it.  Colour Sequence is reading towards the cut end of the cable e.g. RRRY is RED RED RED YELLOW with the Yellow band nearest the end of the cable.

    Listing of Cable Colour Codes
    Codes starting with RED are Category 5 cables feeding
    UPSTAIRS DATA OUTLETS from the patch panel.
    Codes starting with YELLOW are Category 5 cables feeding
    UPSTAIRS CONTROL CABLES for connection to OTTO.
    Codes starting with GREEN are Category 5 cables feeding
    DOWNSTAIRS DATA OUTLETS from the patch panel.
    Codes starting with BLUE are Category 5 cables feeding
    DOWNSTAIRS CONTROL CABLES for connection to OTTO.
    Additionally there are 2.5mm2 Speaker Cables (79/0.2 Figure 8 Twin) to a
    WHOLE HOUSE AUDIO Amplifier located in Node 0
    Was this helpful?
    Thumbs UP Thumbs Down
    Prev Next
    Share this post

    2 comments on “Home Automation Wiring Scheme

    1. Automated Home
      AcmeUK March 13, 2010

      The problem with this is that after 10 years the tape adhesive is shot. Better to use rings of colored heat shrink tube, or similar.

    2. Automated Home
      Otto-Mate March 15, 2010

      Funny you mention that – just a few weeks ago I had to go hunting in the loft for some CAT5s I’d run up there in case we ever moved to C-Bus.

      Here’s a photo of the cables I found – https://automatedhome.com/images/temp/10years.jpg

      Tape code was applied around May 1999 – that photo taken January 2010 (over 10 years), and they are still perfect.

      Maybe you’re using poor quality tape?

      M.